Hi all,

 

In customizing, my inspection type is defined as "one Q-notification by inspection lot".  The linked notification type is A1.

I created an inspection lot.  I created a notification of type B1 with QM01 link to this inspection lot (QMEL-PRUEFLOS).  This B1 notification is already closed.

 

When I record an defect in QE51N for this inspection lot, a new A1 notification is created BUT the closed B1 notification is set in process again.

 

Is there a way to avoid this kind of behavior ?  I just want to create a new A1 notification without reopening the closed one.  Eventually just reopen existing A1 which are already closed but not other type of notifications.

 